8 current controller – Siemens 440 User Manual

Page 182

Advertising
background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

182

6SE6400-5BB00-0BP0

P1611[3]

Acc. torque boost (SLVC)

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

0.0

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 200.0

Enters the dynamic torque boost for the low frequency range for sensorless closed-loop vector control
(SLVC). The parameter is entered as a % referred to the rated motor torque (r0333).

Index:

P1611[0] : 1st. Drive data set (DDS)
P1611[1] : 2nd. Drive data set (DDS)
P1611[2] : 3rd. Drive data set (DDS)

Note:

-

When accelerating and braking, P1611 is added to P1610 and the resulting total torque is converted
into an appropriate current setpoint and controlled (closed-loop).

-

For pure accelerating torques, it is always more favorable to utilize the torque pre-control of the speed
controller (P1496).

3.29.2.8 Current

controller

P1654[3]

Smooth time for Isq setpoint

Min: 2.0

CStat:

CUT

Datatype: Float Unit:

ms

Def:

6.0

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 20.0

Sets time constant of PT1 filter to filter setpoint of torque generating current component in field weakening
range.

Index:

P1654[0] : 1st. Drive data set (DDS)
P1654[1] : 2nd. Drive data set (DDS)
P1654[2] : 3rd. Drive data set (DDS)

P1715[3]

Gain current controller

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

-

Def:

0.25

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 5.00

Enters gain of current controller.

Index:

P1715[0] : 1st. Drive data set (DDS)
P1715[1] : 2nd. Drive data set (DDS)
P1715[2] : 3rd. Drive data set (DDS)

P1717[3]

Integral time current controller

Min: 1.0

CStat:

CUT

Datatype: Float Unit:

ms

Def:

4.1

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 50.0

Enters integral time of current controller.

Index:

P1717[0] : 1st. Drive data set (DDS)
P1717[1] : 2nd. Drive data set (DDS)
P1717[2] : 3rd. Drive data set (DDS)

r1718

CO: Output of Isq controller

Min: -

Datatype: Float Unit:

V

Def:

-

P-Group: CONTROL

Max: -

Displays actual output of Isq current (torque current) controller (PI controller). It contains the proportional
and integral part of the PI controller.

r1719

CO: Integral output of Isq ctrl.

Min: -

Datatype: Float Unit:

V

Def:

-

P-Group: CONTROL

Max: -

Displays integral output of Isq current (torque current) controller (PI controller).

r1723

CO: Output of Isd controller

Min: -

Datatype: Float Unit:

V

Def:

-

P-Group: CONTROL

Max: -

Displays actual output of Isd current (flux current) controller (PI controller). It contains the proportional and
integral part of the PI controller.

r1724

CO: Integral output of Isd ctrl.

Min: -

Datatype: Float Unit:

V

Def:

-

P-Group: CONTROL

Max: -

Displays integral output of Isd current (flux current) controller (PI controller).



Level

2

Level

4

Level

4

Level

4

Level

4

Level

4

Level

4

Level

4

Advertising