SMC Networks SMC TigerStack II SMC6624M User Manual

Page 238

Advertising
background image

9-68

Configuring Advanced Features
Port-Based Virtual LANs (Static VLANs)

Co

nf

ig

u

ri

ng Adva

nce

d

Feat

u

res

Figure 9-54. Example of Tagged and Untagged VLAN Port Assignments

In switch X:

VLANs assigned to ports X1 - X6 can all be untagged because there is
only one VLAN assignment per port. Red VLAN traffic will go out only
the Red ports; Green VLAN traffic will go out only the Green ports,
and so on. Devices connected to these ports do not have to be 802.1Q-
compliant.

However, because both the Red VLAN and the Green VLAN are
assigned to port X7, at least one of the VLANs must be tagged for this
port.

In switch Y:

VLANs assigned to ports Y1 - Y4 can all be untagged because there is
only one VLAN assignment per port. Devices connected to these ports
do not have to be 802.1Q-compliant.

Because both the Red VLAN and the Green VLAN are assigned to port
Y5, at least one of the VLANs must be tagged for this port.

In both switches: The ports on the link between the two switches must be
configured the same. As shown in figure 9-54 (above), the Red VLAN must
be untagged on port X7 and Y5 and the Green VLAN must be tagged on
port X7 and Y5, or vice-versa.

Blue

Server

White

Server

Green

Server

Red

Server

Red

VLAN

Blue

VLAN

White
VLAN

Green
VLAN

Green
VLAN

Red

VLAN

Switch

"X"

5

6

7

4

1

3

2

Switch

"Y"

5

4

1

3

2

Red VLAN: Untagged
Green VLAN: Tagged

Ports 1-6: Untagged
Port 7: Red VLAN Untagged

Green VLAN Tagged

Ports 1-4: Untagged
Port 5: Red VLAN Untagged

Green VLAN Tagged

Advertising