11-8

Troubleshooting
Unusual Network Activity

T

rou

bl

esh

oot

in

g

VLAN-Related Problems

Monitor Port.

When using the monitor port in a multiple VLAN environ-

ment, it can be useful to know how broadcast, multicast, and unicast traffic
is tagged. The following table describes the tagging to expect.

None of the devices assigned to one or more VLANs on an 802.1Q-
compliant switch are being recognized.

If multiple VLANs are being used

on ports connecting 802.1Q-compliant devices, inconsistent VLAN IDs may
have been assigned to one or more VLANs. For a given VLAN, the same VLAN
ID must be used on all connected 802.1Q-compliant devices.

Link Configured for Multiple VLANs Does Not Support Traffic for One
or More VLANs.

One or more VLANs may not be properly configured as

“Tagged” or “Untagged”. A VLAN assigned to a port connecting two 802.1Q-
compliant devices must be configured the same on both ports. For example,
VLAN_1 and VLAN_2 use the same link between switch “X” and switch “Y”.

Figure 11-1. Example of Correct VLAN Port Assignments on a Link

Within Same
Tagged VLAN
as Monitor Port

Within Same
Untagged VLAN
as Monitor Port

Outside of
Tagged Monitor
Port VLAN

Outside of
Untagged Monitor
Port VLAN

Broadcast

Tagged

Untagged

Untagged

Untagged

Multicast

Tagged

Untagged

Untagged

Untagged

Unicast Flood Tagged

Untagged

Untagged

Untagged

Unicast Not
to Monitor
Port

Untagged

Untagged

Untagged

Untagged

Unicast to
Monitor Port

Tagged

Untagged

N/A—Dropped

N/A—Dropped

Switch “Y”

Switch “X”

Link supporting VLAN_1
and VLAN_2

VLAN Port Assignment

Port VLAN_1 VLAN_2

X-3 Untagged Tagged

Port X-3

Port Y- 7

VLAN Port Assignment

Port VLAN_1 VLAN_2

Y-7 Untagged Tagged

Advertising