Monitor-related functions, Monitor selection, Information displayed on the monitors – Panasonic WJ-SX 150A User Manual

Page 14: The display position, Priority lock, Sequence mode

Advertising
background image

15

SLAVE DOWN (Displayed when communication is not
established between the Master and Slave units: for
example, power/cable disconnection)
* “n” is a number.

Notes:

• When pressing the associated numeric button (1 to 5)

while holding down the OSD button, information is
turned on or off.

• When you select the LCN (logical camera number) not

assigned in the system, “NOT ASSIGN” will appear
beside the camera number.

The Display Position

The display position of the information is adjustable with the
joystick on the system controller.

Priority Lock

Priority lock is the function to prevent other operators' con-
trol of a monitor even after the system log-out.
While the priority lock is active, the monitor is operable by
the locking operator and higher-priority operators.

Sequence Mode

Camera images are displayed for a fixed time, and they are
sequentially switched.
The change from a tour sequence into the spot mode is
also possible.
Before use, the parameters of the sequence, such as a
camera or monitor selection and dwell time need to be con-
figured.
There are two sequences:

• Tour sequence
• Group sequence

Tour Sequence

The images through Camera 1 to 99 are displayed on a
given monitor in the desired sequence.
A tour sequence is consisted of 64 steps and up to 32
sequences are configurable.
Up to 30 seconds are selectable as each step's dwell time.
Each step can call the desired preset position of a camera
to be displayed.

Monitor-related Functions

The following functions related to monitors are configurable.

Monitor Selection

It is necessary to select a monitor when controlling the
monitor-related functions, such as camera images or
SETUP MENU.

Information Displayed on the
Monitors

The following information is displayed on monitors.

Time and Date

Time and date are displayed.
The date display is selectable from five patterns, and the
time display is selectable from 24- or 12- hour system.

The date display pattern (Example: August 21, 2001)

21/08/2001
08/21/2001
21/Aug/2001
2001/08/21
Aug/21/2001

Camera Title

The camera number (C01 to C99) and characters (up to 20)
can be configured as a camera title.
The title is displayed in one line.

Monitor Status

The following status is displayed in one line.

Mn (Monitor number)*
Kn (Controller number)*
Tnn (Monitor mode: the example shows the tour
sequence)*
Rn (Recorder number)*

* "n" is a number.

Event

The information related to system operation is displayed.
An alarm control, alarm suspension, and timer event are the
example.

ALARMnn (The alarm is operating.)
ALARMnn ACK (The alarm has been acknowledged.)
Tnn (Timer event: tour sequence number)
LOSS CHnn (the video loss channel number)
ALM SUSPENDED (The alarm is suspended.)
CAM SW LOSS Rn* (Displayed when no camera switch-
ing pulse is supplied from Rn)

08/21/2001 6:50:08 PM

M 1 K 1 T 0 1
C 0 1 c a m e r a t i t l e A L A R M 1 0 *

Clock

Monitor status

Camera title

Event

CH1