Logical camera number – Panasonic WJ-SX 150A User Manual

Page 70

Advertising
background image

73

710 MASTER-SLAVE

MASTER *.**
SLAVE1 ON *.**
SLAVE2 ON *.**
SLAVE3 OFF *.**
SLAVE4 OFF *.**

“CAUTION”
Part of settings are initialized when
the MASTER-SLAVE composition is changed.

Is the MASTER-SLAVE changed? NO

SLAVE 1 to 4

ON:

Select this for units connected in the system.

OFF:

Select this for units not connected in the system.

The factory default setting is OFF.

Notes:

• For Slave units, you can set ON only when the unit with

the previous number is set to ON.

• When you change ON/OFF, part of the setting data will

be initialized according to the master-slave composition

• *. ** is the firmware version of a unit. (For Slave units,

the version is displayed only when ON is selected.)

Is the MASTER-SLAVE changed?

YES:

Select this if you agree that the master-slave com-

position will be changed.

NO:

Select this if you do not agree that the master-slave

composition will be changed.

This message appears only when you try to change
ON/OFF of SLAVE1 to 4.

• To change the setting, select “YES” and press the SET

button. SETUP MENU will be closed, but the setting will
be activated.

• To cancel the setting, select “NO”. The message will

disappear and the cursor moves to the former position.

After the configuration, press the MON (ESC) button. The
monitor display returns to the previous menu.

• LOGICAL CAMERA NUMBER

This menu links to the submenu.
Move the cursor and press the CAM (SET) button to go into
the menu. 720 LOGICAL CAMERA NUMBER will appear on
the monitor.

720 LOGICAL CAMERA NUMBER

SWITCHER=SLAVE1(1 of 4)

CAM LCN CAM LCN
1 1 9 9
2 2 10 10
3 3 11 11
4 4 12 12
5 5 13 13
6 6 14 14
7 7 15 15
8 8 16 16

LCN:LOGICAL CAMERA NUMBER

CAM

720 LOGICAL CAMERA NUMBER

SWITCHER=SLAVE2(2 of 4)

CAM LCN CAM LCN
1 17 9 25
2 18 10 26
3 19 11 27
4 20 12 28
5 21 13 29
6 22 14 30
7 23 15 31
8 24 16 32

LCN:LOGICAL CAMERA NUMBER

720 LOGICAL CAMERA NUMBER

SWITCHER=SLAVE3(3 of 4)

CAM LCN CAM LCN
1 33 9 41
2 34 10 42
3 35 11 43
4 36 12 44
5 37 13 45
6 38 14 46
7 39 15 47
8 40 16 48

LCN:LOGICAL CAMERA NUMBER

720 LOGICAL CAMERA NUMBER

SWITCHER=MASTER(4 of 4)

CAM LCN CAM LCN
1 -- 9 --
2 -- 10 --
3 -- 11 --
4 -- 12 --
5 -- 13 49
6 -- 14 50
7 -- 15 51
8 -- 16 52

LCN:LOGICAL CAMERA NUMBER

CAM

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

Master

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

When Master and Slave 1 are connected

CAM

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

Slave 1

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

Master - - - - - - - - 17 18 19 20 21 22 23 24 25 26 27 28

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

Slave 1

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

Slave 1 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Master - - - - - - - - - - - - - - - - 33 34 35 36 37 38 39 40

When Master, Slave 1 and 2 are connected

Move the joystick to move the cursor.
To select parameters, press the PREV or NEXT button.

SWITCHER:

Select a unit (SLAVE1 to 4 and MASTER*) to

configure the parameters

* In normal connection, only MASTER is displayed.

CAM:

This stands for a camera channel of the unit.

LCN:

This stands for a logical camera number. 1 to 99 is

selectable.

The factory default settings are shown in the diagrams.

When only Master is connected

Advertising