Connection with the system controllers, Connection with the alarm sensors, Data 1 to 4 – Panasonic WJ-SX 150A User Manual

Page 37

Advertising
background image

39

Connection with the Alarm
Sensors

Connect the sensor switches to the unit's alarm port, as
shown in the example.

Notes:

• Alarm inputs that are simultaneous or with very short

intervals will be ignored.
Allow for at least 100 ms interval from one alarm input to
the next.

• Confirm the alarm sensor type (N.O. or N.C.) and con-

figure the system through SETUP MENU (OSD) or WJ-
SX150A Administrator Console.
The factory setting is N.O.

N.O.:

Normally Open alarm contact

N.C.:

Normally Closed alarm contact

• Alarm pins assigned as the time adjusting (TIME) termi-

nals cannot be used as alarm input terminals.

The specification of Recover Input:

5 V DC / 0 V (low-

active)
Recover Input, which resets alarm signals, is Pin No. 13
of the ALARM port. To reset alarm signals, contact GND
and Recover Input.
When you connect Digital Disk Recorder WJ-HD100
Series to the matrix switcher, set the recorder's alarm
polarity to Open-collector low by setting the MODE
switch #6 to off.

25

13

14

1

Alarm
Sensor 1

Alarm
Sensor 2

ALARM

Recover
Input

1
2
3
4
5
6
7
8
9

10
11
12
13

Alarm Input 1
Alarm Input 3
Alarm Input 5
Alarm Input 7
Alarm Input 9
Alarm Input 11
Alarm Input 13
Alarm Input 15
GND
Alarm Output 1
Alarm Output 3
GND
Recover Input

Pin No.

Designation

14
15
16
17
18
19
20
21
22
23
24
25

Alarm Input 2
Alarm Input 4
Alarm Input 6
Alarm Input 8
Alarm Input 10
Alarm Input 12
Alarm Input 14
Alarm Input 16
GND
Alarm Output 2
Alarm Output 4
GND

Pin No.

Designation

Connection with the System
Controllers

Connect the system controller to the DATA 1 to 4 port at the
unit's rear panel with the modular cable.

Notes:

• Up to four system controllers are connectable.
• Connect them in home run.
• In the factory default setting, the DATA 4 port is a

PS·Data terminal. To connect a terminal-mode system
controller to this port, you need to change the data port
setting through SETUP MENU or WJ-SX150A
Administrator Console. (Refer to pp. 74 or 96.)

Matrix Switcher

System controller

System controller

2

DATA 3 DATA 2

TERM

OFF

ON

4

RS485(CAMERA)

LINE

SELECT

RS485(CAMERA)

PS•DATA

DATA 4

DATA HDR

DATA 1

RB

RA

TB

TA

GND

GND

Matrix switcher's rear panel

DATA 1 to 4

TB

TA

RB
RA

DATA1 to DATA4 Port

Advertising