Connection with the Time-lapse VCR (Panasonic Models)

1. Configure the parameters of the Multiplexer functions in the Multiplexer Mode (refer to p. 98) window of WJ-SX150A

Administrator Console.

Note:

To put a file from PC to the unit, select PC in 600 RECORDER in SETUP MENU. (Refer to p. 71.) When VCR is select-

ed, parameter configuration in the Multiplexer Mode window is unavailable.

2. After Step 1, select VCR for 600 RECORDER in SETUP MENU. (Refer to p. 71.)
3. Conform the communication speed (SPEED) for 740 CAMERA/DATA 1- 4 PORT in SETUP MENU to that of the time-lapse

VCR. (Refer to pp. 74 and 75.)
The following parameters are fixed.

Data bit:

7 bits

Parity check:

ODD

Stop bit:

1 bit

4. Connect the matrix switcher’s EXT OUT (REC OUT) to the time-lapse VCR’s VIDEO IN with the coaxial cable.
5. Connect the matrix switcher’s EXT IN (PLAY IN) to the time-lapse VCR’s VIDEO OUT with the coaxial cable.
6. Connect the matrix switcher’s SERIAL to that of the time-lapse VCR with a 9-pin D-sub cable.
7. Connect the matrix switcher’s CAMERA SW IN to the time-lapse VCR’s CAMERA SW OUT with an RCA-pin cable.

Notes:

• Only Panasonic time-lapse VCRs which support RS-232C are usable. (Refer to Cable Specifications on the next page

for details of cables.)

• Both of the time-lapse VCR and PC cannot be connected to the matrix switcher.
• When configuring the system through WJ-SX150A Administrator Console, pull out the time-lapse VCR’s cable and con-

nect the PC’s cable to the serial port.

• To use the alarm recording function, connect the matrix switcher’s all alarm output terminals (Alarm Output 1 to 4) to

the time-lapse VCR’s ALARM IN.

• Be sure to activate auto-recovery for the VCR’s alarm reset function.

MUX

VIDEO IN

CAMERA
SW OUT

GND

S-VIDEO

AUDIO

VIDEO OUT

1

2

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

ALARM

IN

COM

ALARM

RESET IN

ALARM

RECOVER OUT

5

6

7

8

ALARM

OUT

1 SHOT IN

TAPE END

OUT

9

10

11

12

WARNING

OUT

HUMID OUT

REC REVIEW

OUT

13

14

15

16

SERIES

REC IN

TIME

ADJUST IN

TIME

ADJUST OUT

COM

REC OUT

SERIES

REC OUT

Time-lapse VCR

Matrix Switcher

2

DATA 3 DATA 2

SERIAL

ALARM

TERM

OFF

ON

4

2

1

4

3

CAMERA

SW IN

RS485(CAMERA)

LINE

SELECT

MONITOR OUT

EXT IN

(PLAY IN)

EXT OUT

(REC OUT)

RS485(CAMERA)

DATA 4

DATA HDR

PS•DATA

DATA 1

Pin #23(Alarm out 2)

Pin #9(GND)

Pin #24(Alarm out 4)

Pin #10(Alarm out 1)

Pin #11(Alarm out 3)

Pin #13
(Recover Input)