System controller (terminal mode) monitor – Panasonic WJ-SX 150A User Manual

Page 210

Advertising
background image

38

To Control a Recorder and Cameras via the Network

The following is the description of the connection between a recorder and this unit to control the recorder and cameras via the
network.

1. Set the unit address of the recorder to 5 or larger.

(Refer to the recorder’s operating instructions.)

2. Set the [Camera control] setting to “PSD” for all cameras in SETUP MENU of the recorder.
3. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable.
4. Connect the unit’s EXT IN connector to the recorder’s MULTISCREEN OUT connector with a coaxial cable.
5. Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA ports with modular cables.
6. Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER of SETUP MENU or the Recorder window

of WJ-SX150A Administrator Console. (Refer to this unit’s operating instructions.)

Notes:

• Select the PS·Data protocol for the DATA 4 setting.

(Refer to this unit’s operating instructions.)

• If the recorder’s unit address, set in Step 1, and the recorder setting, set in Step 6, are different, the recorder will not be

operable.

• In these connections, you cannot use a PS·Data system controller.
• From system controllers connected to the unit, you cannot control the monitor connected to the MONITOR OUT 1 connec-

tor of recorder.

SIGNAL GND

POWER

AC IN

CAMERA

1

1

2

2

3

3

2

DATA 3 DATA 2

SERIAL

ALARM

TERM

OFF

ON

4

2

1

4

3

CAMERA

SW IN

RS485(CAMERA)

LINE

SELECT

MONITOR OUT

EXT IN

(PLAY IN)

EXT OUT

(REC OUT)

OUT

IN

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

RS485(CAMERA)

DATA 4

DATA HDR

PS•DATA

DATA 1

1

2

IN

OUT

CASCADE

OUT

16

16

3

15

15

14

14

13

2

1

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

VIDEO

AUDIO IN

AUDIO OUT

MONITOR OUT CASCADE IN

MONITOR (VGA)

ALARM/CONTOROL

SERIAL

ALARM

POWER

COPY 1

MODE

EXT STORAGE

10/100BASE-T

RS485(CAMERA)

DATA

AC IN

SIGNAL GND

1

4

2

EXT IN

MONITOR OUT

DATA 4
(PS·Data)

DATA HDR

Matrix Switcher

Recorder*

HUB/Router

MONITOR OUT x

DATA

* Set the recorder’s unit address to 5 or larger.
** LAN: Local Area Network

LAN**

System controller
(Terminal Mode)

Monitor

Advertising