37

(2) ADDENDUM FOR MATRIX SWITCHER WJ-SX150 SERIES:

TO USE DIGITAL DISK RECORDER
WJ-HD300 SERIES/WJ-HD220 SERIES

■ Connection with Digital Disk Recorder WJ-HD300 Series

Notes:

• Refer to service personnel for details on the connection with a recorder to operate via LAN or the Internet.
• Check that the firmware of recorder is Ver. 1.30 or later.
• Only one recorder can be connected to the DATA HDR connector of this unit. (Multiple unit connections, such as cascade

connection, are not available.)

● Basic Connection

The following is the description of the connection between a recorder and this unit to confirm the images from the recorder.

1. Set the unit address of the recorder to 1.
2. Set the [Camera control] setting to “PSD” for all cameras in SETUP MENU of the recorder.
3. Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable.
4. Connect the unit’s EXT IN connector to the recorder’s MULTISCREEN OUT connector with a coaxial cable.
5. Connect the unit’s DATA HDR connector to the recorder’s DATA port with a modular cable.

SIGNAL GND

POWER

AC IN

CAMERA

1

1

2

2

3

3

2

DATA 3 DATA 2

SERIAL

ALARM

TERM

OFF

ON

4

2

1

4

3

CAMERA

SW IN

RS485(CAMERA)

LINE

SELECT

MONITOR OUT

EXT IN

(PLAY IN)

EXT OUT

(REC OUT)

OUT

IN

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

RS485(CAMERA)

DATA 4

DATA HDR

PS•DATA

DATA 1

1

2

IN

OUT

CASCADE

OUT

16

16

3

15

15

14

14

13

2

1

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

VIDEO

AUDIO IN

AUDIO OUT

MONITOR OUT CASCADE IN

MONITOR (VGA)

ALARM/CONTOROL

SERIAL

ALARM

POWER

COPY 1

MODE

EXT STORAGE

10/100BASE-T

RS485(CAMERA)

DATA

AC IN

SIGNAL GND

1

4

2

System controller
(Terminal Mode)

EXT IN

MONITOR OUT

Matrix Switcher

Recorder**

DATA 4*
(PS·Data)

DATA HDR

MONITOR OUT x

DATA

* Connect these ports if you control cameras from the front panel of recorder.
** Set the recorder’s unit address to 1.

Monitor

Notes:

• Make sure the recorder’s unit address is set to 1 through SETUP MENU or WJ-SX150A administrator Console. (Refer to this

unit’s operating instructions.) If another number is selected, you cannot control the recorder.

• To control cameras at the front panel of recorder, connect the DATA 4 connector and the DATA port of recorder with a

modular cable. (PS·Data system controller is not connectable to the DATA 4 connector.)

• From system controllers connected to the unit (WJ-SX150A), you cannot control the monitor connected to the MONITOR

OUT 1 connector of recorder.

SYSTEM CONNECTIONS AND SETUPS (WJ-HD300 SERIES/WJ-HD220 SERIES)