Parameters

• Operator Number

This box displays a list of registered operators.

1-6:

These are operator numbers who are registered as

the factory default setting. Operator Number 1 can-
not be deleted.

Timer:

This operator is used for the priority change of a

timer event. When the timer event's priority is higher
than that of an operator, the event is valid. When an
operator's priority is higher than that of a timer
event, the event is invalid. This operator cannot be
deleted.

• Add Operator Number

This drop-down menu is used for the new operator number
selection. 7 to 16 can be added.

• Operator Group

This group configures each operator's password, level and
priority.

ID:

Enter an operator's ID. From 1 to 99999 are avail-
able.

Password:

Enter a password. From 1 to 99999 are

available.

Level:

Select 1, 2 or 3. Refer to Level Table for details

on level setting.

Priority:

Select the operator's priority from 1 (highest)

to 16 (lowest).

• Camera Access Group

This group configures the camera operation coverage of
each operator.
Click on each camera's checkboxes and determine the
available operation.

1 (View & Control):

The operator can display the cam-

era image on the monitor and control panning/tilt-
ing.

2 (View Only):

The operator can display the camera

image on the monitor, but cannot control the pan-
ning/tilting.

3 (Prohibited):

The operator can neither display the

camera image on the monitor nor control the pan-
ning/tilting.

(Add) button

Adds a new operator to WJ-SX150A.

(Edit) button

The registered parameters become editable by clicking on
this button after selecting the operator number.

(Delete) button

Deletes an operator from WJ-SX150A after you select the
operator.

(OK) button

Saves the configuration and closes the Operator
Registration window.

■

Level Table

This window configures the restrict level of each operation.
The restrict level is classified in Level 1, 2, and 3.

●

How to Display

To display this window, click on the

(Level Table) but-

ton in the main window (p. 80).

●

Parameters

• Permission

Click on each checkbox to classify the following operations
by three levels.

SX150A Setup:

Setting up this matrix switcher system

Camera Setup:

Setting up the cameras

Program Preset Position:

Registering a camera's pre-

set position

Camera Control:

Controlling a camera

Camera Selection:

Selecting a camera

Recorder Setup:

Displaying the recorder's setup menu

Recorder Control:

Controlling the recorder

All Alarm Reset:

Resetting all the alarms

Single Alarm Reset:

Resetting an alarm

Alarm Suspend:

Suspending an alarm

Call Sequence:

Activating a tour or group sequence

Alarm History Display:

Displaying the alarm history

Video Loss History Display:

Displaying the video loss

history

System Status Display:

Displaying the system status

OSD Control:

Controlling on-screen display (Time and

date, monitor status, camera title, and event)

(Save Exit) button:

Saves the configuration and closes the Level Table window.

(EXIT) button

Cancels the configuration and closes the Level Table win-
dow.