Quiet Operation Control

(For Cooling Mode or cooling region of Soft Dry Mode)

•

Purpose of this operation is to provide quite cooling operation compare to normal operation.

•

When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.

•

Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.

•

Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50).
After that, it goes back to Lo cool (However Quiet LED remains on).

•

Manual Airflow Direction:-

−

RPM control during Lo cool

−

RPM control during Hi & Mecool

•

Auto Airflow Direction:-

•

Quiet Mode Operation will stop if:-

−

Quiet mode button is pressed again.

−

Stopped by ON/OFF switch.

−

Timer OFF activates.

−

Powerful mode button is pressed.

−

When change mode to Air Circulation mode.