Note:
# : Fan motor off condition depends on:
a. 1 min over after FM ON. And
b. Air temperature < -3°C (26.6°F) during 1 min.
So the FM Off time is between 5 sec. to 1 min. 5 sec.
D. Indoor condition during protection control
Operation mode
I/D FM
Protection control;
Cooling
Setting speed
Compressor reverse
rotation protection
Soft dry
Cooling zone
Setting speed
Compressor reverse
rotation protection
Soft dry zone
S Lo
Compressor reverse
rotation protection
Heating
Speed
depends
on
I/D
piping temperature
Nil
Automatic
Depends on mode judgement.
#1
#1: I/D fan speed and protection control depends on the operation mode. Then, the condition follow operation mode in table above.