Note:

# : Fan motor off condition depends on:

a. 1 min over after FM ON. And

b. Air temperature < -3°C (26.6°F) during 1 min.

So the FM Off time is between 5 sec. to 1 min. 5 sec.

D. Indoor condition during protection control

Operation mode

I/D FM

Protection control;

Cooling

Setting speed

Compressor reverse
rotation protection

Soft dry

Cooling zone

Setting speed

Compressor reverse
rotation protection

Soft dry zone

S Lo

Compressor reverse
rotation protection

Heating

Speed

depends

on

I/D

piping temperature

Nil

Automatic

Depends on mode judgement.

#1

#1: I/D fan speed and protection control depends on the operation mode. Then, the condition follow operation mode in table above.