Powerful mode operation – Panasonic CS-A9CKPG User Manual

Page 31

Advertising
background image

8.10. Powerful Mode Operation

Purpose of this operation is to be obtain the setting temperature quickly.

1. Cooling and Soft Dry Mode

•

When the Powerful Mode is set, the set temperature will be automatically decreased 3°C (37.4°F) against the present
setting temperature (Lower temperature: 16°C [60.8°F]). This operation automatically will be running under SHi Fan speed
(cooling), Lo- Fan Speed (Soft Dry).

•

Vertical Airflow Direction:-

In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.

In “Auto” setting, the vane will automatically swing up and down. However the upper and lower limit will be shifted 10°
downward.

2. Heating Mode

•

When the Powerful Mode is set, the set temperature will be automatically increased 3°C (37.4°F) against the present setting
temperature (Higher temperature: 30°C [86°F]).

•

The Fan Speed will shift as shown below:

•

Vertical Airflow Direction:-

In “Manual” setting, the vane will automatically shift down 5° lower than previous setting.

In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.

3. Powerful mode will operate for 15 minutes only.

4. Powerful Mode will stop if:

•

Powerful mode button is pressed again.

•

Stopped by ON / OFF switch.

•

Timer-off activates.

•

Quiet mode button is pressed.

•

Operating mode is changed.

31

CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G

Advertising