Airflow direction control – Panasonic CS-A9CKPG User Manual

Page 30

Advertising
background image

1. Vertical Airflow Direction

Thelouver swings up and down as shown above.

The louver does not swing when the Indoor Fan stops
during operation at the upper limit.

Heating Mode

When the intake air temp. reaches 38°C (100.4°F), the
louver is changed from upper to lower limit. When the
intakeair te

mp falls to 35°C (95°F), thelouve

r is

changed from lower to upper limit.

2. Horizontal Airflow Direction

The louver can be selected between 14° - 36° (as
shown above) when pressing Manual Airflow Direction
Selection Button.

The louver can be selected between 0° - 61° (as shown
above)

when

pressing

Manual

Airflow

Direction

Selection Button.

8.9.

Airflow Direction Control

Cooling, Ion and Soft Dry Mode

The left and right airflow direction louvers can be adjusted manually.