Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.

During Soft Dry operation, the indoor fan operates at
Low fan speed.

HEAT – Heating Operation
(for Heat Pump Model only)

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.

Defrosting Operation
Depending on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.

FAN – Air Circulation Operation
(for Cooling Model only)

When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
4°F below the set temperature.
(It is useful when using a heater).

Hi fan speed will not operate when using the air
circulation Fan mode.

Setting the Horizontal Airflow Direction

• Adjust it manually

Notes

If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.

If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

POWER

POWER

TIMER

TIMER

QUIET

QUIET

POWERFUL

POWERFUL

POWERFUL

POWERFUL

ECONOMY

ECONOMY

ECONOMY

ECONOMY

POWER

POWER

TIMER

TIMER

QUIET

QUIET

MANUAL
Five stages of adjustment
can be made between
14 ~ 36 angle.

MANUAL
Five stages of adjustment
can be made between
0 ~ 61 angle.

Heat Pump Model

MANUAL
Five stages of adjustment
can be made between
14 ~ 36 angle.

MANUAL
Five stages of adjustment
can be made between
0 ~ 61 angle.

– When the discharge air

temperature is low such
as at the start of heating
operation, the air blows
in a horizontal direction.
As the temperature
rises, the hot air blows
in a downward direction.

– To stop this operation,

press MANUAL.

HEAT Operation

AUTO

COOL / DRY Operation

AUTO

Swing up/down
Automatically

36°

Swing up/down
Automatically

Move up/down
Automatically

36°

61°

COOL / DRY Operation

AUTO

FAN Operation

AUTO

Setting the Fan Speed
• Press

4

to select:-

FAN

– Low Fan Speed

FAN

– Medium Fan Speed

FAN

– High Fan Speed

AUTO
FAN

Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.

Setting the Vertical Airflow Direction
• Press

5

or

6

to select:-

Cooling Model

Use this air conditioner under the following
conditions:

Heat Pump Model

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature

Minimum Temperature

WBT

73.4

51.8

DBT

109.4

60.8

WBT

78.8

51.8

Indoor

Outdoor

(Unit in °F)

DBT

89.6

60.8

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature-Cooling
(Maximum Temperature-Heating)

Minimum Temperature-Cooling
(Minimum Temperature-Heating)

DBT

89.6

(86)

60.8

(60.8)

WBT

73.4

(–)

51.8

(–)

DBT

109.4
(75.2)

60.8

(23)

WBT

78.8

(64.4)

51.8

(21.2)

Indoor

Outdoor

(Unit in °F)

Cooling Model

SETTING THE TIMER

Ensure that the current time is correct before setting
the timer. The timer cannot be set if the time display
is flashing.

ON-TIMER Operation
To start the air conditioner operation automatically.
• Press

1

to set the operation.

• Press

2

to increase or decrease the time.

• Then press

3

.

• To cancel this operation, press

4

.

OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press

5

to set the operation.

• Press

2

to increase or decrease the time.

• Then press

3

.

• To cancel this operation, press

4

.

Timer Mode Operation Details
• When the ON-Timer is set, operation will start

before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.

• Once the ON/OFF Timer is set, operation will

start/stop at the set time everyday.

• The current time is not displayed when the timers

are set.

• When both timers are used together, the TIMER

mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.

CHECK

AUTO

AUTO HEAT

DRY FAN

COOL

FAN

AUTO

RESET CLOCK

MODE

POWERFUL

ECONOMY

FAN SPEED

AIR SWING

OFF

CANCEL

ON

SET

1

2

3

TIMER

OFF/ON

QUIET

AUTO

MANUAL

3

6

4

1

7

5

2

8

Heat Pump Model

COOL,DRY, –> 15 minutes

in advance

HEAT, AUTO –> 30 minutes

in advance

Cooling Model

COOL,DRY, –> 15 minutes
AUTO

in advance

CONVENIENCE OPERATION

Powerful Mode Operation
To obtain the set temperature quickly.
• Press

6

.

*

Powerful mode indicator (orange) on the indoor
unit will light up.

*

Powerful mode will operate for 15 minutes only.

• To cancel this operation, press once more.

Economy Mode Operation

To save electrical power consumption.
Please use this mode when the room has reached
your desired temperature.
• Press

7

.

*

Economy mode indicator (green) on the indoor unit
will light up.

• Press once more to cancel this operation.

Economy/Powerful Mode Operation Details

• Economy and Powerful operation cannot be

selected simultaneously.

• The changes of the temperature and airflow volume

are automatic.

• The remote control display remains unchanged.
• If operation mode button is pressed, economy or

powerful operation will be cancelled.

• During FAN – Air circulation operation, the powerful

and economy operation are not available.
(for Cooling Model only)

Quiet Mode Operation
To provide quiet operation.
• Press

8

.

*

Quiet mode indicator on the indoor unit will light up.

• To cancel this operation, press once more.

Operation Details
• Air flow sound will reduce during operation.

Airflow

volume

Super Low

Automatic

Economy Mode

Operation

COOL / DRY

HEAT

(for Heat Pump

model only)

Temperature

1°F higher

than set temp.

1°F lower

than set temp.

Airflow

volume

Super High

Automatic

Powerful Mode

Operation

COOL / DRY

HEAT

(for Heat Pump

model only)

Temperature

5°F lower

than set temp.

5°F higher

than set temp.

37

CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G