11.3.6. PIPE INSULATION

DISPOSAL OF OUTDOOR UNIT DRAIN WATER

If a drain elbow is used, the unit should be placed on a
stand which is taller than 3 cm (1.18 inch).

If the unit is used in an area where temperature falls below
0°C (32°F) for 2 or 3 days in succession, it is recommended
not to use a drain elbow, for the drain water freezes and the
fan will not rotate.

1. Remove Top Panel.

2. Remove Control Board Cover (Metal & Resin).

3. Remove Plugs.

4. Fix theconduit connector to theconduit holewith lock-nut,

then secure it.

5. Connecting wire between indoor unit and outdoor unit

should be UL listed or CSA approved 4 × AWG16 wire.

6. Se

curethewireonto thecontrol board with theholde

r

(clamper).

7. Wire connection to the power supply (115V 60Hz) through

circuit breaker.

Connect the UL listed or CSA approved wires (AWG14)
to the terminal board, and connect the other end of the
wires to circuit breaker.

Note: Secure the wires onto the control board
with the holder (clamper).

8. After completed wiring connection, fix back the control

board cover (metal and resin) and the top panel to the
original position with thescrews.

11.3.5. OUTDOOR UNIT ELECTRICAL WIRING

1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap

the insulated piping end to prevent water from going inside the piping.

2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E FOAM

with thickness 6 mm (0.24 inch) or above.