Applicablepiping kit

CZ-3F5, 7AEN (CS-A9CKPG)

CZ-4F5, 7, 10AN (CS-A12CKPG)

SELECT THE BEST LOCATION

INDOOR UNIT

There should not be any heat source or steam near the
unit.

There should not be any obstacles blocking the air
circulation.

A placewhereair circulation in theroom is good.

A place where drainage can be easily done.

A

place

where

noise

prevention

is

taken

into

consideration.

Do not install theunit near thedoor way.

Ensure there is adequate space (indicated by arrows)
from the wall, ceiling, fence or other obstacles.

Recommended installation height for indoor unit shall be
at least 7.5 ft. (2.3 m).

OUTDOOR UNIT

If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.

Keep animals or plants away from the unit as they may
beaffected by thehot air discharged.

Keep the spaces (indicated by arrows) from wall, ceiling,
fence or other obstacles.

Do not place near any obstacles which may cause a
short circuit of thedischarged air.

If piping length is over the common length, additional
refrigerant should be added as shown in the table.