Indoor Unit

Random Auto Restart Control

• Operation is restarted randomly after power

failure at previous setting mode.

Anti-Freezing Control

• Anti-Freezing control for indoor heat

exchanger. (Cooling and Soft Dry)

Economy Operation

• To reduce electrical power consumption.

Indoor Fan Speed Control

• High, Medium and Low.
• Automatic Fan Speed Mode

– Heating : Fan speed varies from Me

→

SSLo in accordance with
indoor heat exchanger.

– Cooling : Fan rotates at Hi, Me and SLo

speed. Deodorizing control is
available.

– Soft Dry : Fan rotates at Lo- speed.

Deodorizing control is
available.

• Automatic air swing and manual adjusted

by remote control for vertical airflow.

• Manually adjusted by hand for horizontal

airflow.

Airflow Direction Control

Automatic Operation Button

• Press for < 5s to operate Automatic

operation mode.
(Used when the remote control cannot be used.)

• Press continuously for 5s or < 10s to

operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)

• Press continuously for 10s and above to

omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.

AUTO

OFF / ON

Operation Indication Lamps (LED)

•

POWER

(Green) ......... Lights up in operation,

blinks in Automatic
Operation Mode judging.

•

QUIET

(Orange) ......... Lights up in Quiet Mode

Operation.

•

TIMER

(Orange) ......... Lights up in Timer

Setting.

•

POWERFUL

(Orange) ... Lights up in Powerful

Mode Operation.

•

ECONOMY

(Green) ...... Lights up in Economy

Mode Operation.

Operation Mode

• Heating, Cooling, Soft Dry and Automatic

Mode.

Powerful Operation

• Reaches the desired room temperature

quickly.

Time Delay Safety Control

• Restarting is inhibited for appro. 3 minutes.

Starting Current Control

Quiet Operation

• To provide extra quiet operation.

7 Minutes Time Save Control

• Cooling Operation only.

• Fan motor is delayed for 1.6 seconds when

compressor starts simultaneously.

30 Minutes Time Save Control

• Heating Operation only.

Hot-Start Control

• At Heating Operation the indoor fan will

operate at SLo speed when indoor heat
exchanger temperature reaches 30°C
(86°F).

Anti Cold Draft Control

• The indoor fan operates at SSLo when the

indoor heat exchanger temperature is low.
(During Heating mode thermal off)

4

CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G