Soft dry mode operation – Panasonic CS-A9CKPG User Manual

Page 19

Advertising
background image

Time Delay Safety Control

Starting Current Control

Anti-Freezing Control

Compressor Reverse Rotation Protection Control

Compressor Protection Control

Automatic Fan Speed Mode

8.2.

Soft Dry Mode Operation

The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.

During Soft Dry operation, the Indoor Fan will operate at Lo- speed.

The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
off, it stops for 6 minutes.

Oncethecompressor stops, it will not start for 3 minutes during Cooling operation.

Same as Starting Current Control for Cooling Mode operation.

Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)

Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)

Same as Compressor Protection Control for Cooling Mode Operation.

When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.

Fan speed rotates at Lo- speed.

Deodorizing Control.

19

CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G

Advertising