Automatic Mode Operation

1. When the Automatic Mode Operation is selected, the indoor fan operates at SLo fan speed for 25 seconds to sense intake air

temperature and determine the 1st operation mode.

2. Operation mode will be determine again after 1 hour of operation, if the room temperature reaches to set temperature and

compressor off time is over 7 minutes 30 seconds continuously.

The present operation mode will be continued, if the room temperature does not reach to set temperature (Compressor keeps running)
eventhough after 1 hour from automatic operation mode started.

Present

Judgement

Next Mode

Mode

Cooling

Soft Dry

Heating

O

O

Cooling

23°C

Cooling

(Judgement:

Not Applicable

(Judgement:

(73.4°F)

Heating

23°C [73.4°F] & Above)

Below 23°C [73.4°F])

O

O

Soft Dry

20°C

Soft Dry

Not Applicable

(Judgement:

(Judgement:

(68°F)

Heating

20°C [68°F] & Above)

Below 20°C [68°F])

O

O

Heating

25°C

Cooling

(Judgement:

Not Applicable

(Judgement:

(77°F)

Heating

Above25°C [77°F])

25°C [77°F] & below)

Automatic Set Temperature
Refer 3. as below.

3. Automatic Set Temperature

For each operation, set temperature will automatically set as shown below.

However it can be selected 2°C (35.6°F) higher or 2°C (35.6°F) lower from standard set temperature by pressing the “Room
Temperature Setting button”.

Operation

Hi

(Standard)

Lo

(+2°C [+35.6°F])

(±0°C [±32°F])

(-2°C [-35.6°F])

Cooling

27°C (80.6°F)

25°C (77°F)

23°C (73.4°F)

Soft Dry

24°C (75.2°F)

22°C (71.6°F)

20°C (68°F)

Heating

23°C (73.4°F)

21°C (69.8°F)

19°C (66.2°F)

The mode judging temperature and standard setting temperature can be increased by 2°C (35.6°F), by open the circuit of
JX1 at indoor electronic controller.