Balance refrigerant of the 2-way, 3-way valves – Panasonic CS-A9CKPG User Manual

Page 59

Advertising
background image

(Gas leakage)

1. Confirm that both the 2-way and 3-way valves are set to

the open position.

2. Connect the charge set to the 3-way valve’s service

port.

Leave the valve on the charge set closed.

Conne

ct thechargehosewith thepush pin to the

service port.

3. Open the valves (Low side) on the charge set and

discharge the refrigerant until the gauge indicates 0.5
to 1 kg/cm

2

G (0.05 to 0.1 MPa) .

If there is no air in the refrigeration cycle [the pressure
when the air conditioner is not running is higher than 1
kg/cm

2

G (0.1 MPa)], discharge the refrigerant until the

gaugeindicates 0.5 to 1 kg/cm

2

G (0.05 to 0.1 MPa). If

this is the case, it will not be necessary to apply a
evacuation.

Discharge the refrigerant gradually; if it is discharged
too suddenly, the refrigeration oil will be discharged.

12.1.4. Balance refrigerant of the 2-way, 3-way valves

Procedure:

59

CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G

Advertising