TROUBLESHOOTING

CONDITION

POSSIBLE CAUSE(S)

POSSIBLE SOLUTIONS(S)

NO SOUND FROM ALL CHANNELS

•

AC power unplugged

•

power not switched on

•

outlet is un-powered

•

Tape Monitor is engaged

•

Check AC cable, connection, and outlet

•

disengage Tape Monitor

NO SOUND FROM SOME CHANNELS

•

Faulty/missing cables

•

<Speaker setup> channel(s) set to “No”

•

power-amp or speaker-connections faulty

•

Check cables

•

check <Speaker setup> menu

•

check power amp, cabling, and speakers

NO SOUND FROM SURROUND CHANNELS

•

No surround listening mode is engaged

•

surround-channels set to “No” on <Speaker
setup> menu

•

surround-channels level set too low on <Levels
setup> menu

•

Select appropriate listening mode

•

correct <Speakers setup> or <Levels setup>
settings

NO SOUND FROM SUBWOOFER

•

Subwoofer is off, unpowered, or improperly
connected

•

subwoofer set to “No” on <Speaker setup>
menu

•

sub level set too low on <Levels setup> menu

•

Power-up subwoofer, check sub’s AC outlet or
check connections

•

correct <Speakers setup> or <Levels setup>
settings

NO SOUND FROM CENTER CHANNEL

•

Source is a 2/0 (etc.) Dolby Digital or DTS
recording without center channel

•

center set to “No” on <Speaker setup> menu

•

center level set too low on <Levels setup> menu

•

Play a known 5.1-channel recording or select
Dolby Pro Logic or Mono mode

•

correct <Speakers setup> or <Levels setup>
settings

NO DOLBY DIGITAL/DTS

•

Source’s digital output is not connected to an
S170i digital input

•

Check connections

S170I DOES NOT RESPOND TO HTR 2 REMOTE

•

Batteries are flat or incorrectly inserted

•

IR transmitter window on remote, or IR receiver
window on S170i is obstructed

•

S170i front panel is in very bright sunlight or
ambient light

•

Check batteries

•

check IR windows and ensure clear line-of-sight
from remote to S170i

•

reduce sunlight/room lighting

S170I DOES NOT RESPOND TO FRONT-PANEL
COMMANDS

•

Microprocessor error

•

Power-down the S170i via the front-panel Power
key and unplug it from the AC outlet

•

wait five minutes, re-connect and power up