Telenetics 56 User Manual

Page 131

Advertising
background image

AT Commands

Page 123

Range:

0, 7, or 128 If an invalid number is entered, it is accepted into the S-

Parameter, but S48 will act as if 128 has been entered.

Default: 7

S48=0 Disable negotiation; bypass the detection and negotiation phases; and

proceed with LAPM.

S48=7

Enable negotiation. (Default.)

S48=128

Disable negotiation; bypass the detection and negotiation

phases; and proceed at once with the fallback action specified in S36. Can be used to
force MNP.

S86 - Call Failure Reason Code

When the modem issues a NO CARRIER result code, a value is written to S86 Register
to help determine the reason for the failed connection. S86 records the first event that
contributes to a NO CARRIER message. The code definitions are:

Range:

0-26

Default:

21

S86=0 Normal hangup, no error occurred.

S86=1 Reserved.

S86=2 Reserved.

S86=3 Call Waiting caused disconnect.

S86=4 Physical carrier loss.

S86=5 No error correction at the other end.

S86=6 No response to feature negotiation.

S86=7 This modem is async only; the other modem is sync only.

S86=8 No framing technique in common.

S86=9 No protocol in common.

S86=10 Bad response to feature negotiation.

S86=11

No sync information from the remote modem.

S86=12 Normal hangup initiated by the remote modem.

S86=13 Retransmission limit reached.

S86=14 Protocol violation occurred.

S86=15 Lost DTR.

S86=16 Received GSTN cleardown.

S86=17 Inactivity timeout.

S86=18 Speed not supported.

S86=19 Long space disconnect.

S86=20 Key abort disconnect.

S86=21 Clears previous disconnect reason.

S86=22 No connection established.

S86=23 Disconnect after three retrains.

S86=24 Call Waiting tone detected.

S86=25 Extension pickup detected.

S86=26

Remote hangup detected.

Advertising