AT Commands

Page 81

5 LAPM error control required; disconnect if error

control is not established.

6 MNP error control required; disconnect if error

control is not established.

8 Initiate V.80 Synchronous Access Mode when

connection is completed, and Data State is
entered (see +ESA and +ITF commands).

9 9Initiate Frame Tunneling Mode when

connection is complete, and Data Mode is
entered

Examples

+ES=6 Enable V.80 Synchronous Access Mode

originator.

+ES=6 Enable V.80 Synchronous Access Mode

originator.
Enable V.80 Synchronous Access Mode
answerer.

+ES=6,,8 Enable V.80 Synchronous Access Mode

originator and answerer.

+ES=3 Enable V.42 with Detection Phase originator.

Disable V.80 Synchronous Access Mode
originator.

+ES=,, 2 Allow LAPM, MNP, or Normal Mode

connection answerer. Disable V.80
Synchronous Access Mode answerer.

+ES=3,,2 Enable V.42 with Detection Phase originator,

allow LAPM, MNP, or Normal Mode connection
answer. Disable Synchronous Access Mode
originator and answerer.

Reporting Current or Selected Values
Command: +ES?
Response: +ES:

<orig_rqst>,<orig_fbk>,<ans_fbk>

Example:

+ES: 3,0,2 For the default setting.
+ES: 6,0,8 For V.80 Synchronous Access Mode originator and
answerer.

Reporting Supported Range of Parameter Values
Command: +ES=?
Response:

+ES: (<orig_rqst> range),( <orig_fbk> range), (<ans_fbk>
range)

Example: +ES:

(0-4,6,7),(0-4),(0-6,8,9)

+EB - Break Handling in Error Control Operation

This extended-format compound parameter controls the break handling in V.42
operation. It accepts three numeric subparameters:

Syntax

+EB=[<break_selection>[,<timed>[,<default_length>]]
]

Defined Value

<break_selection

>

Decimal number 0 specifying that break is to be ignored, i.e.,
not signaled to remote DCE.

<timed> Decimal number 0 specifying that any transmitted V.42 L-

SIGNAL will not indicate break signal length

<default_length> Decimal number 0 specifying that break is not delivered to the

DTE.

Reporting Current or Selected Values