AT Commands

Page 80

Error Control Command

+ES - Error Control and Synchronous Mode Selection

This extended-format command specifies the initial requested mode of operation when
the modem is operating as the originator, optionally specifies the acceptable fallback
mode of operation when the modem is operating as the originator, and optionally
specifies the acceptable fallback mode of operation when the modem is operating as the
answerer. It accepts three numeric subparameters:

Syntax

+ES=[<orig_rqst>[,<orig_fbk>[,<ans_fbk>]]
]

Defined Value

<orig_rqst> Decimal number which specifies the initial requested mode of

operation when the modem is operating as the originator. The
options are:

0 Initiate call with Direct Mode.

1 Initiate call with Normal Mode (also referred to

as Buffered Mode) only.

2 Initiate V.42 without Detection Phase. If V.8 is

in use, disable V.42 Detection Phase.

3 Initiate V.42 with Detection Phase. (Default.)

4 Initiate

MNP.

6 Initiate V.80 Synchronous Access Mode when

connection is completed, and Data State is
entered. (See +ESA and +ITF commands.)

7 Initiate Frame Tunneling Mode when

connection is complete, and Data Mode is
entered.

<orig_fbk> Decimal number which specifies the acceptable fallback mode

of operation when the modem is operating as the originator.

0 LAPM, MNP, or Normal Mode error control

optional. (Default.)

1 LAPM, MNP, or Direct Mode error control

optional.

2 LAPM or MNP error control required;

disconnect if error control is not established.

3 LAPM error control required; disconnect if error

control is not established.

4 MNP error control required; disconnect if error

control is not established.

<ans_fbk> Decimal number which specifies the acceptable fallback mode

of operation when the modem is operating as the answerer or
specifies V.80 Synchronous Access Mode.

0 Direct Mode.

1 Error control disabled, use Normal Mode.

2 LAPM, MNP, or Normal Mode error control

optional. (Default.)

3 LAPM, MNP, or Direct Mode error control

optional.

4 LAPM or MNP error control required;

disconnect if error control is not established.