Fax class 1 and fax class 1.0 commands – Telenetics 56 User Manual

Page 144

Advertising
background image

AT Commands

Page 136

Fax Class 1 and Fax Class 1.0 Commands

Fax I/O Processing

The fax I/O interface supports asynchronous serial and parallel interfaces. The character
format is 8 bits data, no parity, and 1 stop bit. Start and stop elements are removed from
the transmit data and added to the receive data. Both transmit and receive data are
buffered. Flow control using XON/XOFF or RTS/CTS is provided.

Unique control character strings are identified, filtered, or reinserted into the I/O date
stream. These control characters and their resultant action are described below.

DTE-to-Modem Transmit Data Stream

Characters Detected

Action Taken

<DLE><data> Delete <DLE><data> characters.

<DLE><ETX> Recognize as a string terminator and take appropriate action.

<DLE><DLE> Replace with single <DLE> character.

Modem-to-DTE Receive Data Stream

Characters Detected

Action Taken

<DLE>

Insert extra <DLE> ahead of <DLE>.

The modem also identifies the end of a frame by inserting <DLE><ETX> into the data
stream after the FCS bytes.

Fax Mode Selection

Fax Class 1 and Fax Class 1.0 commands are identified in Table A-17. Fax Class 1.0
includes all Fax Class 1 commands.

Advertising