background image

Installing the Auto Gen Start

975-0082-01-01

2–11

Type 2

Type 2 is a three-wire GlowStop configuration recommended for “three-
wire” generators that don’t require a dedicated preheat signal, such as
Onan generators. In this configuration, the start signal is applied for
longer because the generator does its own preheat and cranking while the
start signal is applied.

Figure 2-4 Type 2 and Type 12 connection diagram

Table 2-3 Type 2 relay and timing preset configurations

Relay 1 mode

GlowStop

Relay 3 mode

No function

Gen Run signal hold time

0.5 s

Preheat time

0 s

Preheat to crank delay

0 s

Crank time

30 s

Crank retry time

40 s

Shutdown bypass time

0 s

Start tries

3

18

17

START

16

14

13

12

GEN RUN SIGNAL

GROUND

STOP

Relay 1

Relay 2

5A fuse

5A fuse

AGS wiring harness

Generator wires

Complete overcurrent protection
not shown. Refer to page 2–6.