Stop load, Stop absorb, Stop load –25 stop absorb –25 – Xantrex Technology Automatic Generator User Manual
Page 73: Top absorb”, the, Top absorb” instead, Top absorb”), Or “stop absorb”, the generator, Or “stop absorb”), Top absorb” ha, Stop load”)
 
The Auto Gen Start Menu
975-0082-01-01
3–25
Stop Load
Full name
Stop on Inverter Load Current
Purpose
“Stop Load” sets the Auto Gen Start to stop the generator at a specified 
AC load on the inverter. The “Stop Load” setting applies to situations 
when the Auto Gen Start has started the generator to assist the inverter 
with powering the AC load.
When to use
Use this setting when you have set a value for “Start Load”.
Stop Absorb
Full name
Stop at Absorption Charge Stage
Purpose
The “Stop Absorb” setting allows you to set the Auto Gen Start to stop the 
generator when the inverter/charger has recharged the batteries to the 
Absorption stage.
When to use
Set “Stop Absorb” if you want to deliver a partial charge to your batteries. 
The Auto Gen Start will start and run the generator until the inverter/
charger charges the batteries through the Bulk charge stage (restoring the 
batteries to about 75% of their full charge). The Auto Gen Start stops the 
generator when the inverter/charger determines the batteries have reached 
the Absorption charge stage.
Set “Stop Absorb” if your inverter/charger is using two-stage battery 
charging. If your inverter/charger is set to use three-stage charging, set 
“Stop Float” or “Stop Absorb” to stop the generator. 
Set “Stop Absorb” if battery charging is your main priority for your 
generator (rather than using your generator for powering high AC loads). 
You might also use the “Stop Absorb” setting if your batteries are not 
being charged enough before the Auto Gen Start stops the generator 
because of battery voltage or state of charge.
Values
Default
7.0A to 28.0A (increments of 1 A)
7.0A
Values
Default
Off, On
On