AGS Mode
Purpose
“AGS Mode” is a changeable setting that controls the current operating 
mode of the Auto Gen Start.
When to use
You should change “AGS Mode” when you want to switch between 
automatic generator control and manual generator control.
When the Xanbus system powers up all network-enabled devices, the 
Auto Gen Start is in Manual Off mode. To enable automatic generator 
starts, you must put the Auto Gen Start in Automatic mode.
Automatic
If you would like the Auto Gen Start to start and stop the
generator automatically, select Automatic. The generator can start and 
stop automatically in response to low battery voltage, low battery state of 
charge (requires a DC Monitor in the Xanbus System), AC loads on the 
inverter, thermostat triggers, or exercise time. Automatic mode also has a 
Quiet Time feature, which prevents the generator from starting during 
evening hours or other inconvenient times (see “QT Begin” on page 3–11, 
“QT End” on page 3–13, and “Setting Quiet Time” on page 4–3).
Automatic 
mode overrides
When the Auto Gen Start is in Automatic mode, several settings and 
conditions override automatic start and stop triggers. These overrides 
include, in order of priority:
•
Faults—The Auto Gen Start stops the generator when a fault occurs.
Value Description
Automatic
Automatic mode
ManualOn
Manual on mode
ManualOff
Manual off mode (default mode)
WARNING: Fire and health hazard
Running a generator in an enclosed space produces potentially lethal exhaust 
gases. 
Before putting your RV or boat in storage, disable the Auto Gen Start by putting 
the Xanbus system in Hibernate mode. Do not leave a generator connected to an 
Auto Gen Start otherwise unattended.