Exercise dur, Exercise dur –30, Warning: fire and health hazard – Xantrex Technology Automatic Generator User Manual
Page 78
 
Configuration
3–30
975-0082-01-01
This setting also requires you to set an Exercise Duration (see “Exercise 
Dur” on page 3–30) and an Exercise Time (see “Exercise Time” on 
page 3–31).
When to use
Generators need to run regularly in order to maintain mechanical health 
and performance. If you have no need to use your generator (for example, 
if you are spending long periods of time connected to external AC input, 
or shore power), or if you use your generator for only one season a year, 
setting an exercise period is recommended.
If you run your generator frequently throughout the year, you may not 
need to set an exercise period. Set “Exercise Per” to 0.
Exercise Dur
Full name
Exercise Duration (in minutes)
Purpose
“Exercise Dur” allows you to set how long the generator will run when it 
is exercised.
This setting requires you to set an Exercise Period and an Exercise Time.
When to use
You must set the Exercise Duration when you have set the Exercise 
Period to anything other than 0 (Off).
WARNING: Fire and health hazard
Running a generator in an enclosed space produces potentially lethal exhaust 
gases. 
Before putting your RV or boat in storage, disable the Auto Gen Start by putting 
the Xanbus system in Hibernate mode. Do not leave a generator with equipped 
with an Auto Gen Start otherwise unattended.
Values
Default
0 (Off), 1day to 250days (increments of 1day)
21days
Important:
Consult your generator manual or a service representative from
your generator’s manufacturer for the recommended exercise period.
Values
Default
1min to 250min
30min