Saved Files versus Utility

When saving a file using the "Save File" button, the Configuration Utility stores the configuration
in *.dcf format at a specific version level.

If the *.dcf file is loaded using the “Load File” button into a Configuration Utility at a different level,
the latest Configuration Utility release will load older versions of saved files.

It is recommended to use a saved file, Configuration Utility, and firmware with the same version
level. The following scenarios illustrate how saved files are loaded into the Configuration Utility.

Saved File

Version

Utility

Version

Compatibility Results

V1.03C

V1.01F

The Configuration Utility version (1.01) is lower than the saved file
version (1.03). The Configuration Utility will not have the latest full
set of features required by the saved file. Upon the “Load File”
operation, the Configuration Utility displays the following warning.

This message appears for each Load operation unless you select
“Do not show this message again”.

V1.03C

V1.03F

The Configuration Utility version (1.03) is the same as the saved
file version (1.03). The Configuration Utility will have a matching
set of features with the saved file. The letter at the end of the
version number does not affect compatibility.

V1.03C

V1.05B

The Configuration Utility version (1.05) is greater than the saved
file version (1.03). The Configuration Utility will have a larger
feature set than supported in the saved file. No warning is required.

If the saved configuration version is greater than the Configuration Utility, a warning displays (see
above) when the saved file is loaded into the Configuration Utility. Users are recommended to
find an equivalent version of the Configuration Utility or to check the values loaded.