IMPORTANT: Two options within the Media/Sensor tab can force Auto Calibration:

(1) Power-Up Action = Auto Calibrate
(2) Head Auto Cal = Enable

When option (1) is set, the Auto Calibration procedure happens immediately upon power-up.
When option (2) is set, Auto Calibration happens after the printhead is properly latched and
the Feed key is pressed.

Manual Setup

Manual Calibration is for advanced users only with special
media. The operation calibrates the sensors only. When the
Sensor Calibration window opens

, the values for “Sensor

Intensity”, “Reading Intensity”, and “Threshold Value” are set to
their current va

lues in the printer. The “Current Reading” field is

a read-only field monitored by the printer for comparison with
the set “Reading Intensity” value.

Defaults and explanations for these fields are shown in the table
below with processes for each Media type.

Option

Default

Range

Description

Sensor Intensity

Gap 3

Mark 2

Gap 0-7

Mark 0-3

This value is to set the emitting intensity of the
gap sensor or black mark sensor.

Reading Intensity

Gap 3

Mark 2

Gap 0-7

Mark 0-3

The emitting intensity for the current reading.

Threshold value

512

1023

The reference value to determine whether the
sensor is seeing the gap/label or black
mark/non-black mark.

Current Reading

N/A

0-1023

The receiving sensor signal strength. This is
read only.