Appendix D: List of Parameters

Dry Sensor Calibration (Unloading Menu)

Outgoing Grain Moisture — The dry grain’s actual moisture level (%).

Outgoing Grain Temperature — The dry grain’s actual temperature (°F; °C)

Unload Timer (Unloading Menu)

Unload Timer — The length of time that the unload auger runs to unload the grain. This timer is only avail-
able in staged batch mode.

Unload Speed in Manual Mode (Unloading Menu)

Unload Speeds Entered in — The units of measure (bushels or metric tons per hour, or metering roll
speed %) that the unload speed value is entered in.

Adjusted Speed — The speed that the metering rolls turn at when the Unload Auger switch is in the On
position. Enter the speed value that corresponds to your dryer’s configuration and your chosen drying
operation (full-heat or dry and cool).

Incremental Adjustment — The incremental adjustment of the metering roll speed in manual mode.

Unload Speeds (Unloading Menu)

Unload Speeds Entered in — The units of measure (bushels or metric tons per hour, or metering roll
speed %) that the unload speed value is entered in.

Adjusted Speed — In either the 1-speed temperature control scheme in continuous flow or any of the con-
trol schemes in staged batch, the adjusted speed that the metering rolls turn at when the Unload Auger
switch is in the Auto position.

Incremental Adjustment — The incremental adjustment of the metering rolls’ actual speed in auto mode.

High Speed — In the 2-speed temperature control scheme in continuous flow, a read-only value of the
high-limit metering roll speed. If the grain temperature rises 1°F (0.56°C) above its setpoint, the metering
rolls turn at this speed setting. Adjusting this value incrementally does not alter the value that is set in the
2-Speed Temperature (Continuous Flow) window.

Low Speed — In the 2-speed temperature control scheme in continuous flow, a read-only value of the
low-limit metering roll speed. If the grain temperature drops 1°F (0.56°C) below the setpoint, the metering
rolls turn at this speed setting. Adjusting this value incrementally does not alter the value that is set in the
2-Speed Temperature (Continuous Flow) window.

Speed 5 — In the 5-speed temperature control scheme in continuous flow, a read-only value that is equal
to the reference speed plus the outer speed offset. Adjusting this value incrementally does not alter the
value of the offset that is set in the 5-Speed Temperature (Continuous Flow) window.

Speed 4 — In the 5-speed temperature control scheme in continuous flow, a read-only value that is equal
to the reference speed plus the inner speed offset. Adjusting this value incrementally does not alter the
value of the offset that is set in the 5-Speed Temperature (Continuous Flow) window.

Reference Speed — A read-only value of the metering roll’s setpoint (or reference) speed. Adjusting this
value incrementally does not alter the value of the reference speed that is set in the 5-Speed Temperature
(Continuous Flow) window.

Speed 2 — In the 5-speed temperature control scheme in continuous flow, a read-only value that is equal
to the reference speed minus the inner speed offset. Adjusting this value incrementally does not alter the
value of the offset that is set in the 5-Speed Temperature (Continuous Flow) window.

100

PNEG-1851 Vision N2