Appendix D: List of Parameters

Inner Moisture Offset — The small moisture offset, used to obtain the pair of moisture values that are
closest to the reference moisture. One value is equal to reference moisture minus this offset, whereas the
other is equal to the reference moisture plus this offset.

Outer Moisture Offset — The large moisture offset, used to obtain the pair of moisture values that are fur-
thest from the reference moisture. One value is equal to reference moisture minus this offset, whereas the
other is equal to the reference moisture plus this offset.

Reference Speed — The metering roll’s setpoint (or reference) speed. This is the only true speed parame-
ter that you set; the others are offsets of this value.

Inner Speed Offset — The small speed offset, used to obtain the pair of speed values that are closest to
the reference speed. One value is equal to reference speed minus this offset, whereas the other is equal
to the reference speed plus this offset.

Outer Speed Offset — The large speed offset, used to obtain the pair of speed values that are furthest
from the reference speed. One value is equal to reference speed minus this offset, whereas the other is
equal to the reference speed plus this offset.

Moisture Control Settings: Time (Staged Batch)

Drying Time — The timer that must elapse to end the drying phase.

Moisture Control Settings: Temperature (Staged Batch)

Grain Setpoint — The grain temperature that must be reached to end the drying phase.

Moisture Control Settings: Time and Temperature (Staged Batch)

Drying Time — The timer that must elapse to end the drying phase.

Grain Setpoint — The grain temperature that must be reached to end the drying phase.

Moisture Control Settings: Dual-Setpoint Time (Staged Batch)

Drying Time 1 — The timer that must elapse to make the plenums use the second group of temperature
setpoints.

Drying Time 2 — The timer that must elapse to end the drying phase.

Moisture Control Settings: Dual-Setpoint Temperature (Staged Batch)

Grain Setpoint 1 — The grain temperature that must be reached to make the plenums use the second
group of temperature setpoints.

Grain Setpoint 2 — The grain temperature that must be reached to end the drying phase.

Hardware Setup (System Menu)

Dryer Type — The type of grain dryer that you are using (portable; tower; top).

Number of Modules — The number of modules corresponding to your portable dryer’s configuration (1:
single module; 2: two modules; 3: three modules).

Number of Fans and Heaters — The total number of fans and heaters that are present on your portable
dryer (1, 2, 3, 4, or 6).

PNEG-1851 Vision N2

103