Chapter 2: The Portable Dryer

Table 2-3 The components of the control panel (cont'd.)

Item

Name

Description

d

Fan switch

Controls the fans by way of the following modes:

• Off: the fans do not run

• On: the fans run continuously in both continuous flow and staged

batch modes

• Auto: used in staged batch mode and controlled via a timer, tempera-

ture, or both, the fans run during the drying and cooling phases, but
turn off once the unloading phase begins

e

Unload auger switch

Controls the metering rolls and unload auger by way of the following modes:

• Off: the metering rolls and unload auger do not run

• On: the metering rolls only turn at one speed (in both continuous flow

and staged batch), and the unload auger operates when the metering
rolls are running; also known as manual mode (see

Unloading Grain in

the Initial Run, page 33

)

• Auto: in continuous flow, the metering rolls turn at the speed dictated

by the selected moisture control scheme, and the unload auger runs
continuously; in staged batch mode, the metering rolls and unload
auger only run during the unloading phase

Note the following:

• The Unload Auger switch is illuminated whenever the unload auger is

running

• If auxiliary unloading equipment is configured and connected to your

dryer, the Unload Auger switch also controls the operation of this addi-
tional equipment.

f

Load auger switch

Controls the load auger by way of the following modes:

• Off: the load auger does not run

• On: the load auger runs when the dryer is low on grain and stops when

the dryer wet bin is full; in this mode, the load delay and out of grain
timer are disabled; also known as manual mode

• Auto: the load auger runs when the dryer is low on grain and stops

when the dryer wet bin is full; in this mode, the load delay and out of
grain timer are enabled (for the load delay, see

Minimizing Load Auger

Startups, page 55

; for the out of grain timer, see

Ensuring Dryer Shut-

downs When Supply Is Out of Grain, page 54

)

Note the following:

• The Load Auger switch is illuminated whenever the unload auger is

running

• If auxiliary loading equipment is configured and connected to your

dryer, the Load Auger switch also controls the operation of this addi-
tional equipment.