Messages

Topics Covered in this Appendix

The Status Messages

The Status Messages

Displayed in the status bar, status messages are either general or specific to the chosen drying mode and
constantly notify you of the dryer’s current state.

Table C-1 Status messages for both the continuous flow and staged batch modes

Message

Drying modes

Occurrence

Description

Dryer Started

Continuous flow,
staged batch

Displayed once Start is pressed
on the control panel

The dryer is in operation

Dryer Stopped

Continuous flow,
staged batch

Displayed once Stop is pressed
on the control panel, or Stop
Dryer
is clicked on your dryer’s
remote web application

The dryer is not in operation

Loading

Continuous flow,
staged batch

Displayed when the load auger
is turning

Indicates the time remaining on
the out of grain timer

Drying

Continuous flow,
staged batch

In staged batch, displayed
during the drying phase in either
the time or time and temperature
control scheme, once the drying
time starts

In staged batch, indicates the
time remaining on the drying timer
of the selected control scheme
(time or time and temperature)

Hi-Heat Drying
(time)

Staged batch

Displayed during the drying
phase in the dual-setpoint time
control scheme, once drying
time 1 starts

Indicates the time remaining on
the drying 1 timer

Hi-Heat Drying
(temp)

Staged batch

Displayed during the drying
phase in the dual-setpoint tem-
perature control scheme, before
the grain setpoint 1 is reached

Indicates the difference (in
degrees) between grain setpoint 1
and the grain’s actual
temperature

Low-Heat Drying
(time)

Staged batch

Displayed during the drying
phase in the dual-setpoint time
control scheme, once drying
time 2 starts

Indicates the time remaining on
the drying 2 timer

Low-Heat Drying
(temp)

Staged batch

Displayed during the drying
phase in the dual-setpoint tem-
perature control scheme, before
the grain setpoint 2 is reached

Indicates the difference (in
degrees) between grain setpoint 2
and the grain’s actual
temperature

Cooling

Staged batch

Displayed during the cooling
phase

Indicates the time remaining on
the cooling timer