4 mode menu – B&K Precision 4034 - Manual User Manual

Page 25

Advertising
background image


25

3.6.4 MODE Menu

Selects the output trigger mode: CONT (Continuous), TRIG (Triggered), GATE (Gated), BRST (Burst) and
EXTWID (External pulse).
To select the output mode, press MODE, then press the function key that corresponds to the desired Mode menu
option, as shown:

Mode Menu

F1: CONT - (Continuous) - Selects continuous output.

F2: TRIG - (Triggered) – Triggers one output cycle of the selected pulse for each trigger event.

F3: GATE - (Gated) - Triggers output cycles as long as the trigger source asserts the gate signal.

F4: BRST - (Burst) - Triggers output N output cycles for each trigger event, where N ranges from 2 to 999,999.


F5: EXTWID -
In the external width (EXT WID) pulse mode, the pulse period and width are determined by the

externally applied signal. The pulse generator then applies transition and level parameters to this
signal in order to generate the pulse. The period, width and delay may be changed, but their change
has no effect on the pulse, and their values are not displayed. The trigger mode may not be changed
while the external width pulse mode is enabled.


External Pulse