500ns to 10us
5us to 100us
50us to 1ms
500us to 10ms


4.12.1.19 Pulse Polarity

This command is used to control the polarity of the pulse, which may be normal or complemented. The
COMPement and INVerted parameters are aliases: either may be used.

COMMAND TYPE:

Setting or Query

SETTING

Syntax:

[:SOURce]:PULSe:POLarity<ws><Option>

Arguments:

Type:

Character

Options:

NORMal – Normal polarity

COMPlement – complemented

INVerted – complemented
Examples:

:PULS:POL NORM

:PULS:POL INVerted

QUERY

Syntax:

[:SOURce]:PULSe:POLarity?

Examples:

:PULS:POL?

Response:

NORM | COMP

4.12.1.20 Channel Dependency

This command is used to control the dependency of channel 2. It can select either for channel 2 to be
an independent channel, or set it to be dependent on channel 1. This means that channel 2 will have the
same clock and trigger, as well as same frequency and period as channel 1.

COMMAND TYPE:

Setting or Query

SETTING

Syntax:

:SOURce:COUP <Option>

Arguments:

Type:

Character

Options:

ON or 1– Dependent on channel 1

OFF or 0 – Independent

Examples:

:SOUR:COUP 1

:SOUR:COUP OFF

QUERY

Syntax:

:SOURce: COUP?

Examples:

:SOUR:COUP?

Response:

1 | 0