4.12.2 OUTPut Subsystem

The Output Subsystem controls characteristics of the source’s output. The OUTPut command controls
whether the output is ON or OFF.

COMMAND TYPE:

Setting or Query

SETTING

Syntax:

[:OUTPut]:STATe<ws><Boolean>

Arguments:

Type:

Boolean

Examples:

:OUTP:STAT ON

:OUTP OFF

QUERY

Syntax:

:OUTPut[:STATe]?

Response:

0 | 1

MODEL 4034 ONLY:

To control output of channel 2, change the subsystem from :OUTP to :OUTP2. For example, to
turn on output of channel, send command :OUTP2:STAT ON.

4.12.3 Trigger Subsystem

The Trigger Subsystem is used to control the waveform triggering. It is not all SCPI compatible. The
command structure is as follows:

:TRIGger

:MODE CONTinuous | TRIGger | GATE | BURSt
:BURSt <NRf>
:SOURce <MANual> | INTernal | EXTernal | BUS
:TIMer <NRf>
:LEVel <NRf>
:DELay <NRf>
:SLOPe POSitive | NEGative


MODEL 4034 ONLY:

To control the trigger mode of channel 2, change the subsystem from :TRIG to :TRIG2. For
example, to check trigger mode of channel 2, send the command :TRIG2:MODE?

4.12.3.1 Trigger Mode

This command is used to set the trigger mode. It is not a standard SCPI command.

COMMAND TYPE:

Setting or Query

SETTING

Syntax:

:TRIGger:MODE<ws><option>

Arguments:

Type:

Character

Options:

CONTinuous

TRIGger

GATE