BURSt

Examples:

:TRIG:MODE CONT

:TRIG:MODE BURS

QUERY

Syntax:

:TRIGger:MODE?

Response:

CONT | TRIG | GATE | BURS

4.12.3.2 Trigger Source

This command is used to select the trigger source, for use in the Trigger, Gate and Burst trigger modes.

COMMAND TYPE:

Setting or Query

SETTING

Syntax:

:TRIGger:SOURce<ws><option>

Arguments:

Type:

Character

Options:

MANual – Front panel MAN key

BUS – GPIB trigger (GET or *TRG)

INTernal – Internal trigger

EXTernal – External trigger

Examples:

:TRIG:SOUR BUS

:TRIG:SOUR INT

QUERY

Syntax:

:TRIGger:SOURce?

Response:

MAN | BUS | INT | EXT

4.12.3.3 Burst Count

Used to set the number of cycles to be output in the BURST mode. It is not a standard SCPI command.

COMMAND TYPE:

Setting or Query

SETTING

Syntax:

:TRIGger:BURSt<ws><value>

Arguments:

Type:

NRf

Range:

2 to 999999

Rounding:

To integer value

Examples:

:TRIG:BURS 100

QUERY

Syntax:

:TRIGger:BURSt?

Response:

NRf

Examples:

:TRIG:BURSt?

4.12.3.4 Internal Trigger Rate

Sets the rate of the internal trigger.

COMMAND TYPE:

Setting or Query

SETTING

Syntax:

:TRIGger:TIMer<ws><value>[units]