Triggering on video lines, Application of x-y function, Pplication of – B&K Precision 2532B - Manual User Manual

Page 168: Unction

Advertising
background image

168

Triggering on Video Lines

To trigger on the video lines, follow these steps:

1. Press the “TRIGGER MENU” button to see the trigger menu.
2. Press the top “option” button and select “Video”
3. Press the “Sync” option button and select “Line Num” and turn the

universal knob to set a specific line number.

4. Press the “Standard” option button and select “NTSC”.
5. Turn the “Time/Div” knob to see a complete video line across the

screen.

6. Turn the “Volts/Div” knob to ensure that the entire video signal is

visible on the screen.

Application of X-Y Function


Viewing Impedance Changes in a Network

Connect the oscilloscope to monitor the input and output of the circuit

To view the input and output of the circuit in an XY display, follow these

steps:

1. Press the “CH 1” MENU button and set the Probe option

attenuation to 10X.

2. Press the “CH 2” MENU button and set the Probe option

attenuation to 10X.

3. Set the switch of the probe to 10X.