B&K Precision 2532B - Manual User Manual

Page 78

Advertising
background image

78

Table 25 - Set Trigger Mode to Video Trigger Function Menu 2

Option

Setting

Instruction

Sync

All lines
Line Num
Odd field
Even Field

Select appropriate video sync.

Standard

NTSC
Pal/Secam

Select the video standard for sync and
line number count.

Next Page

Page 1/2

Enter the second page of Alternative
trigger menu.

Table 26 - Set Trigger Mode to Slope Trigger Function Menu 1

Option

Setting

Instruction

Type

Alternative

The trigger signal comes from two vertical
channels when you use alternative trigger.
In this mode, you can observe two
irrelative signals at the same time.

Source

CH1
CH2

Set trigger type information for CH1
signal.
Set trigger type information for CH2
signal.

Mode

Slope

Set trigger type of the vertical channel
signal to slope trigger.

Polarity

(Normal

)

(Inverted)

Normal triggers on the negative edge of
the sync pulse.
Inverted triggers on the positive edge of
the sync pulse.

Next Page

Page 1/2

Enter the second page of Alternative
trigger menu.

Advertising