5.

Push the ¼” household feed line fully into the elbow and reinstall the
locking clip between the elbow and collet.

6.

Make sure the Control Cable is connected between the water distiller head
and the storage tank by turning the plug until the splines lock and then turn
the locking ring until finger tight. See the Control Cable Connection
Diagram
below.

Control Cable Connection Diagram

Boiling Tank Drain Valve Diagram

7.

Refer to the Boiling Tank Drain Valve Diagram above. Close the boiling
tank drain ball valve at the rear of the water distiller (ball valve is shown in
the closed position). If the water distiller is equipped with the PWS AED-1
Automatic Electric Drain the ball valve should be in the open position.

8.

Tighten the saddle valve handle completely by turning clockwise to pierce
the water supply line (copper or plastic water line only). Open the water
supply to the water distiller by turning the saddle valve handle counter-
clockwise. Check for leaks.