Hydrotech Precision-PWS 8-5 OWNERS GUIDE User Manual

Page 43

Advertising
background image

43

PROBLEM

CAUSE

C) Steam or water is
escaping from the top of the
cooling coil.

1. The cooling coil is equipped with a gas release

vent, a very small hole in the top of the coil. This
is to release certain volatile gases. Steam may
escape from this hole. This is normal.

2. If little or no water is being produced the cooling

coil may have become disconnected from the
boiling tank. Call Service Center.

D) Charcoal Filter is very hot
and steam is escaping from
the filter.

1. The fan switch is turned off. Check Switch.
2. Fan motor is not running properly, may be

defective, or the fan motor switch may be
defective. Call Service Center.

3. Cooling coil fins are plugged with dust, dirt, or

grease. Remove and clean or take to a service
center for maintenance.

4. The location of the water distiller does not

provide enough airflow for good cooling. Move
the water distiller to an area with more air
movement.

E) Boiling tank will not fill
with water.

1. The self-piercing saddle valve is turned off.

Check and turn on if necessary.

2. The direct water feed line may be obstructed or

kinked. Check and fix.

3. The water switch and/or the power switch are

off. Check switches.

4. The float in the boiling tank may be stuck.

Check by opening boiler tank and lifting gently
up on ball float.

5. Opening for water feed line inside the boiling

tank may be scaled up. Check by opening boiler
tank and checking scale build up.

6. Manual reset button has tripped. See A) 3.

above.

7. Storage tank is over 2/3 full. Normal Operation.
8. Water Fill Micro Switch Faulty. Call Service

Center.

9. Solenoid valve is faulty. Call Service Center.

F) Water distiller may start to
boil, then shuts off. It may
restart after cooling down.
Very small amount of water
is produced.

1. Faulty Reset button. After letting water distiller

cool down and trying to reset several times, call
Service Center.

Advertising