Using the Digital Display

This section explains the messages shown on the digital display,
which is illustrated here for your convenience.

Segment A — Indicates in which mode the unit is operating:

PROGRAM — The unit is in the programming mode, which
allows you to program vacuum time and refrigerant weight or to
review the existing program.
HOLD — This mode is used while changing a refrigerant tank
or to interrupt the vacuum/charging/recovery cycles.
AUTOMATIC — Indicates that the unit is running in a given
cycle and will automatically stop when the cycle is complete.

Segment B — Indicates that the unit is either evacuating the A/C
system or recovering, recycling, or recharging refrigerant or that
the unit is ready to be programmed for one of these functions:

VACUUM
• With PROGRAM, indicates that the unit is ready to be pro-

grammed for vacuum.

• With AUTOMATIC, indicates that the vacuum pump is running;

the number displayed counts down in minutes and seconds,
showing the amount of time remaining.

• With HOLD, indicates that HOLD/CONT was pressed to

interrupt the vacuum cycle.

RECYCLE
• With AUTOMATIC, indicates the unit is recycling refrigerant

from the tank.

CHARGE
• With PROGRAM, indicates that the unit is ready to be pro-

grammed for the amount of refrigerant to be charged into the
A/C system; on the keypad enter the charge in pounds and
hundredths of a pound or kilograms, depending on the model
you have.

• With AUTOMATIC, indicates the unit is charging refrigerant

into the A/C system; the number shown on the digital display
counts down, showing the remaining amount of refrigerant to
be dispensed.

• With HOLD, indicates that HOLD/CONT was pressed to

interrupt the charging cycle; the number shown on the digital
display is the amount of refrigerant remaining to be charged
into the A/C system; to continue charging, press HOLD/CONT
again.

RECOVER
• With AUTOMATIC, indicates the unit is recovering refrigerant

from the A/C system and shows the amount of refrigerant
recovered in pounds or kilograms, depending on the model
you have.

OIL(OUNCES) OR OIL(GRAMS)
• Lights up as a reminder to drain the oil separator after each

job.

Segment C — Shows a number or a coded error message on
the digital display that indicates the unit’s operating status or any
specific problems.

NUMBER
Indicates the vacuum time in minutes or the refrigerant weight
in pounds or kilograms, depending on the model you have.

ERROR CODES

• CAL — Calibrate the scale.
• CH-F — Change the filter-drier.
• CL-L — Low side clearing routine in progress.
• CON — Continuous; the vacuum pump will run continuously.
• CPL — Complete; cycle process is finished.
• FIL — Filter change process.
• FULL — Refrigerant recovery tank is full.
• HI-P — High pressure, system pressure is above 350 psi.
• OIL — Change the vacuum pump oil.
• U-HI — High pressure to the vacuum pump.
• SCAL — Scale problem; scale may be broken or disconnected,

or tank weight has exceeded 80 pounds (36 kilograms).

• 99LB — The maximum amount displayed during recovery is 99

kilograms; reset the unit.

Segment D — Indicates that refrigerant is low—approximately
six pounds (or 2.7 kg) of refrigerant is left in the tank. If the tank is
low, either replace the tank or add refrigerant following the
instructions in “Adding Refrigerant To The Tank.”

VACUUM

+ PROGRAM

= Program unit for

vacuum

VACUUM

+ AUTOMATIC

= Vacuum pump is

running

VACUUM

+ HOLD

= Interrupted vacuum

cycle

RECYCLE

+ AUTOMATIC

= Unit is recycling

refrigerant

CHARGE

+ PROGRAM

= Program unit for charge

CHARGE

+ AUTOMATIC

= Unit is charging A/C

system

CHARGE

+ HOLD

= Interrupted charging

cycle

RECOVER

+ AUTOMATIC

= Unit is recovering

refrigerant

Quick Reference Chart

Segment B messages

Diagram of Digital Display

Diagramm der Digitalanzeige