Hciwritepintype, Hciwritescanenable, Hciwritepintype hciwritescanenable – Teledyne LeCroy BTTracer_Trainer - BTTrainer Users Manual User Manual
Page 234

216
CATC BTT
RAINER
2.11
C
HAPTER
User’s Manual
Comments
Sets the maximum time the local Link Manager will wait for a baseband
page response from the remote device at a locally initiated connection
attempt.
Example
result = HCIWritePageTimeout(0x4000);
HCIWritePINType
HCIWritePINType(PINType)
Return value
•
“Success”
•
“Failure”
•
“Invalid parameter”
Comments
Determines whether the Host supports variable PIN codes or only a fixed
PIN code.
Example
result = HCIWritePINType(0);
HCIWriteScanEnable
HCIWriteScanEnable(AccessibleMode)
Return value
•
“Success”
•
“Timed out”
•
“Failure”
Parameter
Meaning
Default Value
Comments
PINType
PIN type:
0=Variable
PIN;
1=Fixed PIN
Range is 0 to 1.
Parameter
Meaning
Default Value
Comments
Accessible
Mode
Access mode
to set Merlin's
Wand
“GENERAL_
ACCESSI-
BLE”
Mode can be one of:
“GENERAL_ACCESSIBLE”,
“NOT_ACCESSIBLE”,
“CONNECTABLE_ONLY”