PacketLength
2 Bytes
0x0000 - MaxPacketSize
Cannot be longer than the maximum packet size
of the selected min(PacketType,
maxHCICommandLength).
Currently it’s set to 224 Bytes.
In Closed Loopback mode, set to 0 (not
applicable)
Data
From 0 to
MaxPacket
Size Bytes
If TestScenario does not require a predefined data
pattern, this parameter will be used. Otherwise,
it’ll be ignored.
Data length is defined by the PacketLength
parameter. If it is 0, this parameter will be ignored.
ErrorType
2 Bytes
0x0008
HEC error injection
0x0010
CRC error injection
0x0040
FEC 2/3 error injection
0x0080
FEC 1/3 header error injection
0x0100
FEC 1/3 payload error injection
0x0200
Wrong AM_ADDR of the slave.
0x0000
No error
0x0201 – 0xFFFF
Reserved