MTR response for a Set Point Step, Time-based(PTYP = TI)
Register #

1200

1201

1202

1203

1204

1205

1206

1207

1208

1209

1210

Parameter

File

Step

Type

SP

Hour

Min

Sec

*

*

*

*

MTR response for a Set Point Step, Rate-based(PTYP = RATE)
Register #

1200

1201

1202

1203

1204

1205

1206

1207

1208

1209

1210

Parameter

File

Step

Type

SP

*

*

*

Rate

*

*

*

MTR response for a Soak Step
Register #

1200

1201

1202

1203

1204

1205

1206

1207

1208

1209

1210

Parameter

File

Step

Type

*

Hour

Min

Sec

*

*

*

*

PROGRAM command for a Set Point Step, Time-based(PTYP = TI)
Register #

1250

1251

1252

1253

1254

1255

1256

1257

1258

1259

1260

Parameter

2

File

Step

Type

SP

Hour

Min

Sec

*

*

*

PROGRAM command for a Set Point Step, Rate-based(PTYP = RATE)
Register #

1250

1251

1252

1253

1254

1255

1256

1257

1258

1259

1260

Parameter

2

File

Step

Type

SP

*

*

*

Rate

JF

*

PROGRAM command for a Soak Step
Register #

1250

1251

1252

1253

1254

1255

1256

1257

1258

1259

1260

Parameter

2

File

Step

Type

*

Hour

Min

Sec

*

*

*

PROGRAM command for a Jump Loop Step
Register #

1250

1251

1252

1253

1254

1255

1256

1257

1258

1259

1260

Parameter

2

File

Step

Type

*

*

*

*

*

JF

JS

PROGRAM command for a Link File Step
Register #

1250

1251

1252

1253

1254

1255

1256

1257

1258

1259

1260

Parameter

2

File

Step

Type

*

*

*

*

*

*

*

PROGRAM command for an End Step Step
Register #

1250

1251

1252

1253

1254

1255

1256

1257

1258

1259

1260

Parameter

2

File

Step

Type

*

*

*

*

*

*

*

MONITOR (MTR) Command

READ only

Register: 1200 (You must request 23 registers)

START (STRT) Command

WRITE only

Register:

1250 1251 1252

Value:

1

File # Step #

SET command, sets the current profile FILE and STEP.

WRITE only

Register:

1250 1251 1252

Value:

3

File # Step #

STEP (STP) Command

READ the current file and step

Register:

1201 (You must request 23 registers)

Response will be the same as the PROGRAM commands below,
(1201 = 1251, 1202 = 1252 etc.)

WRITE (program) the specified file and step.

(You must send a "*" (-9999) if a register is disabled or unavailable)

NOTE:
"*" means the
parameter is
not available.
The value will
be -9999.

981,

982,

983, 984

5.14

Data Communications with the Watlow Series 988 Family

Command Summary Series 981-984, Chapter 5

Advertising