Temperature/process Controller Prompt Table

986, 987,

988

, 989

Data Communications with the Watlow Series 988 Family

6.9

Command Summary Series 986-989, Chapter 6

Name

Description

Read (?) and/or Write (=) Syntax

Range

data.1

data.2

Modbus
address

OT3

Output 3 Action

? <sp> OT3 <cr>

0 = None

78

= <sp> OT3 <sp> data.2 <cr>

1 = Alarm 3
2 = Alarm 3 reverse acting

OTPT

Lockout Output

? <sp> OTPT <cr>

0 = No lockout

117

Menu

= <sp> OTPT <sp> data.2 <cr>

1 = Read only
2 = No read or write
Default: 0

OTY1

Output 1 Hardware

? <sp> OTY1 <cr>

0 = None

132

1 = SSR 0.5A

OTY2

Output 2 Hardware

? <sp> OTY2 <cr>

2 = SSR 0.5A with suppression

133

6 = Switched dc

OTY3

Output 3 Hardware

? <sp> OTY3 <cr>

8 = Relay 5A Form C

134

9 = Relay 5A Form C with suppr.

OTY4

Output 4 Hardware

? <sp> OTY4 <cr>

10 = Relay 5A Form A/B

135

11 = Relay 5A Form A/B with suppr.
13 = Process output
14 = Voltage retransmit
15 = Current retransmit
16 = Power supply
17 = Comms EIA-232
18 = Comms EIA -485 / EIA-422
19 = Comms EIA-485 / EIA-232

PB1A

Proportional Band

? <sp> PB1A <cr>

if DFL = 0, then 0 to 9999

21

Output 1 PID Set A

= <sp> PB1A <sp> data.2 <cr>

if DFL = 1, then 0.0 to 99.9% of span
Default: 25

°

F, 14

°

C, 25 units or 3.0%

PB1B

Proportional Band

? <sp> PB1B <cr>

if DFL = 0, then 0 to 9999

34

Output 1 PID Set B

= <sp> PB1B <sp> data.2 <cr>

if DFL = 1, then 0.0 to 99.9% of span
Default: 25

°

F, 14

°

C, 25 units or 3.0%

PB2A

Proportional Band

? <sp> PB2A <cr>

if DFL = 0, then 0 to 9999

27

Output 2 PID Set A

= <sp> PB2A <sp> data.2 <cr>

if DFL = 1, then 0.0 to 99.9% of span
Default: 25

°

F, 14

°

C, 25 units or 3.0%

PB2B

Proportional Band

? <sp> PB2B <cr>

if DFL = 0, then 0 to 9999

40

Output 2 PID Set B

= <sp> PB2B <sp> data.2 <cr>

if DFL = 1, then 0.0 to 99.9% of span
Default: 25

°

F, 14

°

C, 25 units or 3.0%

PIDA

Lockout PID Set A

? <sp> PIDA <cr>

0 = No lockout

114

Menu

= <sp> PIDA <sp> data.2 <cr>

1 = Read only
2 = No read or write
Default: 0

PIDB

Lockout PID Set B

? <sp> PIDB <cr>

0 = No lockout

115

Menu

= <sp> PIDB <sp> data.2 <cr>

1 = Read only
2 = No read or write
Default: 0

Table 6.9 -

OT3 to PIDB

ç

CAUTION:
Avoid writing <=>
continuously,
such as ramping
set points or
repetitive loops, to
the Series 986-989
EEPROM memory.
Continuous writes
may result in
premature control
failure, system
downtime and
damage to
processes and
equipment.