IM 01E20F12-01E

5-13

5. EXPLANATION OF BASIC ITEMS

Flow Rate (%)

1 0 0 . 0

%

F R

F0505.eps

Decimal point is always to the first place.

Out Value

Flow rate is displayed together with the units set in
OUT_SCALE, the maximum number of figures is six.

- 1 2 3 . 4 5 6

k g a l /

i n

m

F R

F0506.eps

In the case of Characterization Type is "Direct "
decimal point location of the data becomes as follows.

OUT

OUT_SCALE.

_SCALE. Decimal Point

Decimal Point

Place

Place

of

of

decimal

decimal

Example

Example

0

0

123

1

1

123.4

2

2

3

123.45

3

123.456

Other

Auto

Refer to below

T0507.eps

When OUT_SCALE. Decimal Point is set as Other,
decimal point location of the data becomes as follows.

OUT.Value

Place of decimal

Example

-999999<OUT.Value

Յ

-10000

0

-222222

-10000<OUT.Value

Յ

-1000

1

-4444.1

-1000<OUT.Value

Յ

-100

2

-555.12

-100<OUT.Value<100

3

-66.123

100

Յ

OUT.Value<1000

2

555.12

1000

Յ

OUT.Value<10000

1

4444.1

10000

Յ

OUT.Value

Յ

999999

0

222222

T0508.eps

When the flow data exceeds the maximum number of
figures six, then "84:Disp Over Wng" message is
displayed.

9 9 9

.

9 9

l / h

9

2 3 4 5 6

M l

1

F T L

F R

p

D

8 4 :

i s

n g

r

W

e

O v

F0507.eps